Unofficial Notice of Invitation to Bid (NIB)
Burbank City is seeking bids from qualified and interested contractors for the following project titled, Water Main Line Stopping & Valve Insertion Services, identified under Solicitation ID: 2026-002. Work is to be performed near 275 E Olive Ave, Burbank, CA 91502, USA in Los Angeles County.
General Project Description
This project is a Price Agreement for Water Main Line Stopping & Valve Insertion Services for the City of Burbank Water and Power (BWP) Department, Water Division. The scope involves providing all necessary labor, equipment, material, and supervision to perform line stopping and valve insertion services on pressurized water mains on an as-needed basis. Line stopping is required to isolate existing pipes (ductile iron, cast iron, steel, and concrete cylinder pipes) when shutdowns cannot be accomplished by existing valves. Valve insertion involves installing new valves on live water mains without service interruption, utilizing non-rising stem, resilient wedge, ductile iron body gate valves manufactured per AWWA C-509 or C-515 standards with a 250 psi working pressure (e.g., Insta-Valve 250 Patriot or approved equal). The project also includes welding on tapping sleeves, requiring the contractor to submit a welding plan for BWP review and approval that complies with AWWA Standard C206-17 Field Welding of Steel Water Pipe, with a specified branch size of 6 inches for items 13-16. The City of Burbank Water and Power will handle excavation, shoring, thrust blocks, backfill, pavement, traffic control, and excavation permits.
General Bid Items
- Quantity: LS Unit: LS Work Item: Line Stop 30” Pressurized Water Main; Specifications: Cast Iron, or CCP, or Steel
- Quantity: LS Unit: LS Work Item: Line Stop 24” Pressurized Water Main; Specifications: Cast Iron, or CCP, or Steel
- Quantity: LS Unit: LS Work Item: Line Stop 20” Pressurized Water Main; Specifications: Cast Iron, or CCP, or Steel
- Quantity: LS Unit: LS Work Item: Line Stop 18” Pressurized Water Main; Specifications: Cast Iron, or CCP, or Steel
- Quantity: LS Unit: LS Work Item: Line Stop 16” Pressurized Water Main; Specifications: Cast Iron, or CCP, or Steel
- Quantity: EA Unit: EA Work Item: Insert 24" Valve on Pressurized Water Main; Specifications: Ductile Iron/Cast Iron, Lined or Unlined, non-rising stem, resilient wedge, ductile iron body, manufactured per AWWA C-509 or C-515, 250 psi working pressure, Insta-Valve 250 Patriot or approved equal.
- Quantity: EA Unit: EA Work Item: Insert 20" Valve on Pressurized Water Main; Specifications: Ductile Iron/Cast Iron, Lined or Unlined, non-rising stem, resilient wedge, ductile iron body, manufactured per AWWA C-509 or C-515, 250 psi working pressure, Insta-Valve 250 Patriot or approved equal.
- Quantity: EA Unit: EA Work Item: Insert 16" Valve on Pressurized Water Main; Specifications: Ductile Iron/Cast Iron, Lined or Unlined, non-rising stem, resilient wedge, ductile iron body, manufactured per AWWA C-509 or C-515, 250 psi working pressure, Insta-Valve 250 Patriot or approved equal.
- Quantity: EA Unit: EA Work Item: Insert 12" Valve on Pressurized Water Main; Specifications: Ductile Iron/Cast Iron, Lined or Unlined, non-rising stem, resilient wedge, ductile iron body, manufactured per AWWA C-509 or C-515, 250 psi working pressure, Insta-Valve 250 Patriot or approved equal.
- Quantity: EA Unit: EA Work Item: Insert 10" Valve on Pressurized Water Main; Specifications: Ductile Iron/Cast Iron, Lined or Unlined, non-rising stem, resilient wedge, ductile iron body, manufactured per AWWA C-509 or C-515, 250 psi working pressure, Insta-Valve 250 Patriot or approved equal.
- Quantity: EA Unit: EA Work Item: Insert 8" Valve on Pressurized Water Main; Specifications: Ductile Iron/Cast Iron, Lined or Unlined, non-rising stem, resilient wedge, ductile iron body, manufactured per AWWA C-509 or C-515, 250 psi working pressure, Insta-Valve 250 Patriot or approved equal.
- Quantity: EA Unit: EA Work Item: Insert 6" Valve on Pressurized Water Main; Specifications: Ductile Iron/Cast Iron, Lined or Unlined, non-rising stem, resilient wedge, ductile iron body, manufactured per AWWA C-509 or C-515, 250 psi working pressure, Insta-Valve 250 Patriot or approved equal.
- Quantity: LS Unit: LS Work Item: Weld -on a Tapping Sleeve of Various Sizes on a Pressurized 30” Concrete Steel Cylinder Pipe; Specifications: Branch size 6 inches, welding complies with AWWA Standard C206-17 Field Welding of Steel Water Pipe.
- Quantity: LS Unit: LS Work Item: Weld -on a Tapping Sleeve of Various Sizes on a Pressurized 24” Concrete Steel Cylinder Pipe; Specifications: Branch size 6 inches, welding complies with AWWA Standard C206-17 Field Welding of Steel Water Pipe.
- Quantity: LS Unit: LS Work Item: Weld -on a Tapping Sleeve of Various Sizes on a Pressurized 20” Concrete Steel Cylinder Pipe; Specifications: Branch size 6 inches, welding complies with AWWA Standard C206-17 Field Welding of Steel Water Pipe.
- Quantity: LS Unit: LS Work Item: Weld -on a Tapping Sleeve of Various Sizes on a Pressurized 18” Concrete Steel Cylinder Pipe; Specifications: Branch size 6 inches, welding complies with AWWA Standard C206-17 Field Welding of Steel Water Pipe.
NAICS Classification
NAICS 237110 – Water and Sewer Line and Related Structures Construction, NAICS 221310 – Water Supply and Irrigation Systems, NAICS 238910 – Site Preparation Contractors
Records and Due Date
This bid opportunity was entered into BidAmerica on February 16, 2026, and was last updated on February 16, 2026. All bids and/or proposals are due on February 26, 2026.
Contractors may log in or create a free BidAmerica account to view full project documents, plans, specifications, addenda, submission requirements, and more project details issued by Burbank City.
Legal Disclaimer
All bidders are responsible for reviewing and verifying all official bid documentation directly from the issuing agency. BidAmerica aggregates public bid information for advertisement purposes for contractors and government agencies convenience. This Notice of Invitation to Bid is for reference purposes only and is not an official or complete representation of any documents issued by Burbank City. BidAmerica does not guarantee the accuracy, completeness, or timeliness of any information displayed and shall not be held liable for any errors, omissions, misinterpretations, or damages resulting from reliance on this summary. Contractors must obtain all official information—including plans, specifications, addenda, deadlines, submission requirements, qualifications, and bidding conditions—directly from Burbank City prior to bidding.