Helix Water District is seeking bids from qualified and interested contractors for the following project titled, Impressed Current Cathodic Protection Project, identified under Solicitation ID: CIP24004. Work is to be performed near 7811 University Ave, La Mesa, CA 91942, USA in San Diego County.

General Project Description

This project involves the furnishing of all labor, equipment, materials, tools, services, and transportation necessary for the construction of an AQ1 Impressed Current Cathodic Protection system. The work includes the installation of a deep well anode bed, a rectifier assembly, and associated appurtenances. Key tasks encompass electrical installations, trench excavation and backfill, temporary paving, pavement repair, and traffic control, all in compliance with Water Agencies’ Standards Specifications and California Public Works & Civil Engineering Standards.

General Bid Items

  • Quantity: 1  Unit: LS  Work Item: Mobilization (not to exceed 5% of total bid price).
  • Quantity: 1  Unit: EA  Work Item: Installation of deep well anode bed.
  • Quantity: 1  Unit: EA  Work Item: Installation of rectifier assembly, Specifications: Universal air-cooled standard line model ASAI 40-25 or approved equal, 120/240 volt single phase AC input, 40 VDC 25 ADC output.
  • Quantity: 1  Unit: EA  Work Item: Installation of AC meter pedestal, Specifications: 100A main breaker, 20A double pole breaker, 20A single pole breaker, Myers MEUG16-M100-SD or approved equal.
  • Quantity: 1  Unit: LS  Work Item: Drilling for deep well anode beds.
  • Quantity: 1  Unit: LS  Work Item: Electrical installations for cathodic protection system.
  • Quantity: 1  Unit: EA  Work Item: Installation of AC Outlet, Specifications: 120V/20A receptacle with its own 20 amp breaker from meter pedestal.
  • Quantity: 1  Unit: EA  Work Item: Installation of shunt panel board, Specifications: Micarta, 1/4-inch thick, anode shunts and test/reference cell leads, double-nutted brass bolts, nuts, and lock washers per UL 486.
  • Quantity: 1  Unit: LS  Work Item: Furnishing and installing copper or brass terminal lugs, Specifications: Per UL 486.
  • Quantity: 1  Unit: LS  Work Item: Installation of wire cables and conductors, Specifications: Buried at 24-inch depth minimum, free of splices, aligned parallel to and within 2-inches of conduit/wire run.
  • Quantity: 1  Unit: LS  Work Item: Burying warning tape, Specifications: 12-inches below grade and above underground conductors and conduits.
  • Quantity: 1  Unit: LS  Work Item: Installation of conduits, Specifications: Secured with double locknuts (one outside, one inside) where entering anode junction box.
  • Quantity: 1  Unit: LS  Work Item: Installation of watertight fittings, couplings, connections, and sealing unused openings for conduits and boxes.
  • Quantity: 1  Unit: LS  Work Item: Trench excavation and backfill, Specifications: In accordance with Water Agencies’ Standards Specifications, sawcut edges to minimum 6” depth or ground, include disposal of existing materials and import of new backfill.
  • Quantity: 1  Unit: LS  Work Item: Temporary paving, Specifications: Place daily upon backfilled trenches in paved areas, in accordance with Public Works Construction (Greenbook) Standards Specifications.
  • Quantity: 1  Unit: LS  Work Item: Pavement repair, Specifications: Repair existing asphalt pavement damaged during construction, including trench resurfacing, replacement of striping and pavement legends.
  • Quantity: 1  Unit: LS  Work Item: Traffic control, Specifications: In accordance with Agency(s) of Jurisdiction requirements and California Manual on Uniform Traffic Control Devices.
  • Quantity: 1  Unit: LS  Work Item: Activation and adjustment of the CP System.
  • Quantity: 1  Unit: LS  Work Item: Anode lead wire inspection and testing.

NAICS Classification

237110 – Water and Sewer Line and Related Structures Construction (Includes excavation, backfill, piping, and related civil work often associated with cathodic protection systems for pipelines)., 238210 – Electrical Contractors and Other Wiring Installation Contractors (For the installation of rectifier assemblies, electrical wiring, and other components of the cathodic protection system)., 237990 – Other Heavy and Civil Engineering Construction (Encompasses specialized civil engineering work like impressed current cathodic protection systems, deep well anode bed installation, and associated site preparation not specifically categorized elsewhere)., 238910 – Site Preparation Contractors (For general excavation, trenching, rock removal, and earthwork activities).

Records and Due Date

This bid opportunity was entered into BidAmerica on November 27, 2025, and was last updated on December 15, 2025. All bids and/or proposals are due on December 16, 2025.

Contractors may log in or create a free BidAmerica account to view full project documents, plans, specifications, addenda, submission requirements, and more project details issued by Helix Water District.

Legal Disclaimer

All bidders are responsible for reviewing and verifying all official bid documentation directly from the issuing agency. BidAmerica aggregates public bid information for advertisement purposes for contractors and government agencies convenience. This Notice of Invitation to Bid is for reference purposes only and is not an official or complete representation of any documents issued by Helix Water District. BidAmerica does not guarantee the accuracy, completeness, or timeliness of any information displayed and shall not be held liable for any errors, omissions, misinterpretations, or damages resulting from reliance on this summary. Contractors must obtain all official information—including plans, specifications, addenda, deadlines, submission requirements, qualifications, and bidding conditions—directly from Helix Water District prior to bidding.

Impressed Current Cathodic Protection Project - Bid Opportunity | BidAmerica